ABB AC500-S Safety User Manual page 234

Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Configuration and programming
AC500-S libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Function block-
Table 46: FB-specific error codes
specific error
DiagCode
and status
codes
C001
C002
C003
C004
Table 47: FB-specific status codes (no error):
DiagCode
0000
8000
8001
234
State name
State description and output setting
Reset Error1 Static Reset detected in state 8001.
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = TRUE
Reset Error
Static Reset detected in state C004.
2
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = TRUE
Reset Error
Static Reset detected in state 8011.
3
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = TRUE
Safety Lost
Safety lost, guard opened or guard unlocked.
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = TRUE
State name
State description and output setting
Idle
The function block is not active (initial state).
Ready = FALSE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = FALSE
Guard
Guard is locked.
Closed and
Ready = TRUE
Locked
S_GuardLocked = TRUE
S_UnlockGuard = FALSE
Error = FALSE
Init
Function block was activated and initiated.
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = FALSE
3ADR025091M0208, 12, en_US
2020/06/19

Advertisement

Table of Contents
loading

Table of Contents