Program Example - ABB AC500-S Safety User Manual

Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Safety application examples
Example 2: muting > Program example

7.3.4 Program example

S 7_S_ AOPD _In
StartTest_LC1
Fig. 130: Access protection at a material gate - application program page 1
350
TR U E
S1_S _EStopIn
TR U E
FALSE
S9_ Reset
TR U E
S6_ S_ GuardSw itch
S6_ S_ GuardSw itch
T#0 m s
TR U E
FALSE
S9_ Reset
TR U E
S2_ M utingSwitch11
S3_ M utingSwitch12
S4_ M utingSwitch21
S5_ M utingSwitch22
L1_S _ M utingL am p
T#30 s
App lM utingEnab le 1
TR U E
S9_ Reset
SF_LightCurtain_1
SF_TestableSafetySensor
TR U E
Activate
S_OSSD _In
S_OSSD _Out
StartTest
T#100m s
TestTim e
TR U E
NoExternalTest
TestExecuted
TR U E
S
_
t S
r a
R t
s e
t e
FALSE
S_AutoR eset
S0_Reset
Reset
3ADR025091M0208, 12, en_US
SF_EmergencyStop_1
SF_Eme rgencyStop
Activate
R eady
S_EStopIn
S_EStopOut
S_StartReset
S_AutoReset
D iagCode
Reset
SF_GuardMonitoring_1
SF_Gua rdMo nitoring
Activate
R eady
S_ GuardSw itch1
S_ GuardM onitoring
S_ GuardSw itch2
Disc repan cyTim e
D iagCode
S_ StartReset
S_ AutoReset
Reset
SF_M utingSeq_1
SF_MutingSeq
Activate
R eady
S_ AOP D_In
S_AOPD _Out
M utingS w itch11
S_ M utingA ctive
M
t u
n i
g
S
w
c t i
h
1
2
M utingS w itch21
D iagCode
M utingS w itch22
S_ M utingLa m p
M axM utingTim e
M utingEnab le
S_ StartReset
Reset
Read y
S_ TestOut
S _TestOut_LightCurtain _S8
TestPoss ible
TestPossible_L C 1
TestExecuted_ LC 1
E
r r
r o
Error _LightC urtain 1
D iagC ode
D iag _LightC urtain1
Error
Error_EStop 1
D iag_ EStop1
Error
Error_Guard 1
D iag_ Guard 1
AND
S_M utingA ctive_ L1
E
r r
r o
Error_M uting 1
D iag_ M uting1
Page 2
S_SafeC ontrol
2020/06/19

Advertisement

Table of Contents
loading

Table of Contents