Function block-
Table 43: FB-specific error codes
specific error
DiagCode
and status
codes
C001
C002
C003
C004
C005
C006
2020/06/19
State name
State description and output setting
Error 1 B1
S_Button1 was TRUE on FB activation.
Ready = TRUE
Error = TRUE
S_TwoHandOut = FALSE
Error 1 B2
S_Button2 was TRUE on FB activation.
Ready = TRUE
Error = TRUE
S_TwoHandOut = FALSE
Error 1
The signals at S_Button1 and S_Button2 were TRUE on FB acti-
B1&B2
vation.
Ready = TRUE
Error = TRUE
S_TwoHandOut = FALSE
Error 2 B1
S_Button1 was FALSE and S_Button 2 was TRUE after 500 ms
in state 8005.
Ready = TRUE
Error = TRUE
S_TwoHandOut = FALSE
Error 2 B2
S_Button1 was TRUE and S_Button 2 was FALSE after 500 ms
in state 8005.
Ready = TRUE
Error = TRUE
S_TwoHandOut = FALSE
Error 2
S_Button1 was TRUE and S_Button 2 was TRUE after 500 ms in
B1&B2
state 8005 or 8006. This state is only possible when the states of
the inputs (S_Button1 and S_Button2) change from divergent to
convergent (both TRUE) simultaneously when the timer elapses
(500 ms) at the same cycle.
Ready = TRUE
Error = TRUE
S_TwoHandOut = FALSE