ABB AC500-S Safety User Manual page 189

Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Name
Data type
pIODesc
POINTER
VAR_OUTPUT
cons_nr_R
BOOL
Toggle_d
BOOL
FV_activated_S
BOOL
OA_Req_S
BOOL
WD_timeout
BOOL
CE_CRC
BOOL
Device_Fault
BOOL
iPar_OK_S
BOOL
Host_CE_CRC
BOOL
2020/06/19
AC500-S libraries > SafetyBase_PROFIsafe_LV200_AC500_V22.lib
Initial value
Description, parameter values
NULL
Internal input parameter (internal use only!)
FALSE
This parameter is for debugging purposes only.
It is set when the F-Device has reset its consecutive
number counter in PROFIsafe communication
FALSE
This parameter is for debugging purposes only.
It is a device-based toggle bit indicating a trigger to
increment the virtual consecutive number within the
F-Host
FALSE
With input devices this variable indicates if TRUE
that the driver is delivering fail-safe values "0" to the
F-Host program for every input value.
With output devices this variable indicates if TRUE
that every output is set to fail-safe values "0" (default
behavior) or F-Output device specific value controlled
by the "activate_FV" signal
FALSE
This variable indicates a request for acknowledgment
prior to the resumption of a safety function. In case
the F-Host driver or F-Device detects a communica-
tion error or F-Device fault, fail-safe values will be
activated. F-Device driver then sets the variable
OA_Req_S (= TRUE) as soon as the fault/error has
been eliminated and operator acknowledgment is
possible. Once the acknowledgment occurred (OA_C
= TRUE) the F-Device driver will reset the request
variable OA_Req_S (= FALSE)
FALSE
This parameter is for debugging purposes only.
It is set to TRUE if the F-Device is recognizing a
communication failure, i.e. if the watchdog time in the
F-Device is exceeded
FALSE
This parameter is for debugging purposes only.
It is set if the F-Device is recognizing a communica-
tion failure, i.e. if the consecutive number is wrong
(detected via CRC2 error in V2-mode) or the data
integrity is violated (CRC error)
FALSE
This parameter is set to TRUE if there is a malfunc-
tion in the F-Device (e.g., under- or overvoltage)
Ä [3].
FALSE
This parameter is set to TRUE when F-Device has
new parameter values assigned
FALSE
This parameter is for debugging purposes only.
This parameter is set to TRUE if communication fault
(CRC error on F-Host side) occurred.
3ADR025091M0208, 12, en_US
Configuration and programming
Ä [3].
Ä [3].
Ä [3].
Ä [3].
Ä [3].
Ä [3].
Ä [3].
189