Configuration and programming
AC500-S libraries > SafetyBlocks_PLCopen_AC500_v22.lib
The SF_EnableSwitch FB processes the confirmation of the "safe mode" state via the "S_Safe-
tyActive" parameter. On implementation in an application of the safe mode without confirmation,
a static TRUE signal is connected to the "S_SafetyActive" parameter.
The S_AutoReset input shall only be activated if it is ensured that no hazardous situation can
occur when the PES is started.
Table 60: FB name: SF_EnableSwitch
Name
Data type
VAR_INPUT
Activate
BOOL
S_SafetyActive
BOOL
S_Enable-
BOOL
SwitchCh1
S_Enable-
BOOL
SwitchCh2
S_AutoReset
BOOL
Reset
BOOL
VAR_OUTPUT
Ready
BOOL
S_EnableSwitchOut BOOL
Error
BOOL
DiagCode
WORD
274
Initial value
Description, parameter values
Ä Table 16 "General input parameters" on page 192
FALSE
FALSE
Variable or constant.
Confirmation of the safe mode (limitation of the
speed or the power of motion, limitation of the range
of motion).
FALSE: Safe mode is not active.
TRUE: Safe mode is active.
FALSE
Variable.
Signal of contacts E1 and E2 of the connected
enable switch.
FALSE: Connected switches are open.
TRUE: Connected switches are closed.
FALSE
Variable.
Signal of contacts E3 and E4 of the connected
enable switch.
FALSE: Connected switches are open.
TRUE: Connected switches are closed.
Ä Table 16 "General input parameters" on page 192
FALSE
Ä Table 16 "General input parameters" on page 192
FALSE
FALSE
Ä Table 17 "General output parameters"
on page 193
FALSE
Safety related output: Indicates suspension of guard.
FALSE: Disable suspension of safeguarding.
TRUE: Enable suspension of safeguarding.
Ä Table 17 "General output parameters"
FALSE
on page 193
Ä Table 17 "General output parameters"
16#0000
on page 193