ABB AC500-S Safety User Manual page 261

Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

DiagCode
C005
C006
C007
C008
Table 56: FB-specific status codes (no error):
DiagCode
0000
8000
2020/06/19
State name
State description and output setting
Parameter
DiscTime11_12, DiscTime21_22 or MaxMutingTime value out of
Error
range.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = TRUE
Error Timer
Timing error: Active muting time (when S_MutingActive = TRUE)
MaxMuting
exceeds MaxMutingTime.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = TRUE
Error Timer
Timing error: Discrepancy time for switching MutingSwitch11 and
MS11_12
MutingSwitch12 > DiscTime11_12.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = TRUE
Error Timer
Timing error: Discrepancy time for switching MutingSwitch21 and
MS21_22
MutingSwitch22 > DiscTime21_22.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = TRUE
State name
State description and output setting
Idle
The function block is not active (initial state).
Ready = FALSE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
AOPD Free
Muting not active and no safety demand from AOPD. If timers
from subsequent muting are still running, they are stopped.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = FALSE
Error = FALSE
3ADR025091M0208, 12, en_US