ABB AC500-S Safety User Manual page 271

Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

Table 59: FB-specific status codes (no error):
DiagCode
0000
8000
8001
8002
8003
8005
8011
2020/06/19
State name
State description and output setting
Idle
The function block is not active (initial state).
Ready = FALSE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
AOPD Free
Muting not active and no safety demand from AOPD. If timers
from subsequent muting are still running, they are stopped.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = FALSE
Error = FALSE
Init
Function block was activated.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
Safety
Safety demand detected by AOPD, muting not active.
Demand
Ready = TRUE
AOPD
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
Wait for
Safety demand or errors have been detected and are now
Reset
cleared. Operator acknowledgment by Reset required.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
Safe
Safety function activated.
Ready = TRUE
S_AOPD_Out = FALSE
S_MutingActive = FALSE
Error = FALSE
Muting Start
Muting sequence is in starting phase after rising trigger of
1
S_MutingSwitch11. Monitoring of DiscTimeEntry is activated.
Ready = TRUE
S_AOPD_Out = TRUE
S_MutingActive = FALSE
Error = FALSE
3ADR025091M0208, 12, en_US
Configuration and programming
AC500-S libraries > SafetyBlocks_PLCopen_AC500_v22.lib
271

Advertisement

Table of Contents
loading

Table of Contents