Name
L1_S_MutingLamp
S7_S_AOPD_In
K1_S_EDM
K2_S_EDM
S9_Reset
S0_Reset
ApplCtrl1
StartTest_LC1
ApplMutingEnable1
Table 98: Outputs
Name
S_EDM_Out_K
S_MutingActive_L1
S_TestOut_LightCur-
tain_S8
Errors
DiagCodes
TestPossible_LC1
TestExecuted_LC1
Table 99: Local variables
Name
S_SafeControl
2020/06/19
Data type
Description
BOOL
Muting lamp monitor signal L1
BOOL
OSSD from light curtain S7
BOOL
Feedback from external device K1 (actuator)
BOOL
Feedback from external device K2 (actuator)
BOOL
Reset safety demand by user S9
BOOL
Reset error by user S0 (derived from functional application)
BOOL
Signal controlling the actuator, enabled by safety loop (derived from
functional application)
BOOL
Signal starting test of light curtain S7 (derived from functional applica-
tion)
BOOL
Signal enabling start of the muting sequence (derived from functional
application)
Data type
Description
BOOL
Drives actuator via K1 and K2
BOOL
Drives muting lamp L1
BOOL
Test output for light curtain S8
BOOL
Represents all errors of the used FB (connected to functional applica-
tion)
WORD
Represents all diagnostic codes of the used FB (connected to functional
application)
BOOL
Indicates to the functional application that an automatic sensor test of
the light curtain is possible.
BOOL
Indicates to the functional application the successful execution of an
automatic sensor test of the light curtain.
Data type
Description
BOOL
Indicates the status of the safety guards (TRUE = safety enabled)
3ADR025091M0208, 12, en_US
Safety application examples
Example 2: muting > Declaration of used variables