DiagCode
8003
8012
8004
8014
8005
4.6.4.8
SF_TwoHandControlTypeII
Standards
Requirements
EN 574:1996
Clause 4, Table 1, Type II.
5.1 Use of both hands / simultaneous actuation.
5.2 Relationship between output signal and input signals.
5.3 Completion of the output signal.
5.6 Reinitiation of the output signal.
6.3 Use of DIN EN 954-1 category 3 (can only be realized by NO and NC switches together
with antivalent processing)
ISO 12100-2:2003
4.11.4: Restart following power failure/spontaneous restart
2020/06/19
State name
State description and output setting
Wait for
Waiting for rising trigger at Reset.
Reset
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE
Guard
Guard completely opened.
Opened
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE
Wait for
S_GuardSwitch1 has been switched to TRUE - waiting for
Guard-
S_GuardSwitch2; discrepancy timer started.
Switch2
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE
Wait for
S_GuardSwitch2 has been switched to TRUE - waiting for
Guard-
S_GuardSwitch1; discrepancy timer started.
Switch1
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE
Guard
Guard closed. Waiting for Reset, if S_AutoReset = FALSE.
Closed
Ready = TRUE
S_GuardMonitoring = FALSE
Error = FALSE