Name
Data type
StartTest
BOOL
NoExternalTest
BOOL
S_StartReset
BOOL
S_AutoReset
BOOL
Reset
BOOL
TestTime
TIME
VAR_OUTPUT
Ready
BOOL
S_OSSD_Out
BOOL
S_TestOut
BOOL
TestPossible
BOOL
TestExecuted
BOOL
2020/06/19
Initial value
Description, parameter values
FALSE
Variable.
Input to start sensor test. Sets "S_TestOut" and starts
the internal time monitoring function in the FB.
FALSE: No test requested.
TRUE: Test requested.
FALSE
Constant.
Indicates if external manual sensor test is supported.
FALSE: The external manual sensor test is sup-
ported. Only after a complete manual sensor
switching sequence, an automatic test is possible
again after a faulty automatic sensor test.
TRUE: The external manual sensor test is not sup-
ported.
An automatic test is possible again without a manual
sensor switching sequence after faulty automatic
sensor test.
Ä Table 16 "General input parameters" on page 192
FALSE
FALSE
Ä Table 16 "General input parameters" on page 192
FALSE
Ä Table 16 "General input parameters" on page 192
T#10ms
Constant. Range: 0 ... 150ms.
Test time of safety sensor.
Ä Table 17 "General output parameters"
FALSE
on page 193
FALSE
Safety related output indicating the status of the
ESPE.
FALSE: The sensor has a safety-related action
request or test error. TRUE: The sensor has no
safety-related action request and no test error.
TRUE
Coupled with the test input of the sensor.
FALSE: Test request issued.
TRUE: No test request.
FALSE
Feedback signal to the process.
FALSE: An automatic sensor test is not possible.
TRUE: An automatic sensor test is possible.
FALSE
A positive signal edge indicates the successful exe-
cution of the automatic sensor test.
FALSE:
- An automatic sensor test was not executed yet.
- An automatic sensor test is active.
- An automatic sensor test was faulty.
TRUE: A sensor test was executed successfully.
3ADR025091M0208, 12, en_US
Configuration and programming