Avaya G430 Manual page 413

Administering branch gateway
Hide thumbs Also See for G430:
Table of Contents

Advertisement

Displaying and clearing profiles
Launching and cancelling a test
Displaying test results
Healing trunks
Displaying corrections
Summary of integrated analog testing commands
Hardware support for integrated analog testing
• The MM711 hardware vintage 30 and above
• The MM714 hardware vintage 10 and above, and the MM716
For detailed information about accepted values and recommended corrections, see Analog
Test and Heal User Guide .
Types of tests
Tests typically make a series of measurements in frequencies between 100Hz and 3400Hz in
100Hz increments. You can run the following tests:
Noise test: Noise is the measure of unwanted signals in the transmission path. After the call
is established and while the far end is silent, the Branch Gateway collects the noise level.
Receive-loss test: After the call is established and while the tone (or tones) specific to the
responder sequence is being received, the Branch Gateway collects the signal level at the
reference frequency and compares it with the reference level. The difference in decibel
between the level sent and the level received is the loss.
Crosstalk test: While the analog port under test is in a call and both ends of the call are silent,
the crosstalk port establishes another call and plays a sequence of tones. The Branch Gateway
collects during that time the tone level for different frequencies on the port under test.
Balance test: This test measures trans-hybrid loss. After the call is established and while the
far end is silent, the Branch Gateway transmits a tone and measures the reflected signal level.
The transmitted tone level minus the reflected tone level is the trans-hybrid loss at that
frequency.
Match test: This test matches hybrid balance. Stored in the integrated analog testing firmware
is a group of hybrid balance coefficient sets. Each entry in the group balances the hybrid
against a different loop impedance. The match test executes a balance test for each set of
coefficients and determines which set best matches the loop.