Keysight Technologies EPM-P Series Programming Manual page 54

Power meters
Hide thumbs Also See for EPM-P Series:
Table of Contents

Advertisement

1
Power Meter Remote Operation
:SYST:ERR? <read string>
SERV:SENS:TYPE?
SENS:FREQ 800MHZ
SENS:BW:VID:LOW
SENS:SWE1:OFFS:TIME:0.00001
SENS:SWE1:TIME0.015
SENS:SWE2:TIME0.090
INIT:CONT ON
TRIG:SOUR INT
TRIG:LEV:AUTO OFF
TRIG:LEV -20.00DBM
TRIG:HOLD 0.02
DISP:WIND1:FORM SNUM
DISP:WIND2:FORM DNUM
CALC1:FEED1 "POW:AVER ON SWEEP1"
CALC2:FEED1 "POW:PTAV ON SWEEP1"
CALC4:FEED1 "POW:PTAV ON SWEEP2"
54
The system error query should return "0:
No Error"
The sensor type query should return one
of the following:
E9321A|E9322A|E9323A|
E9325A|E9326A|E9327A
The iDEN setup is only valid with these
sensors
Sets the measurement frequency to
800 MHz
Select low video bandwidth
Sets gate1 start point to 10
trigger
Sets gate1 length to 15 ms
Sets gate2 length to 90 ms
Puts meter in "wait for trigger" state
Selects internal trigger
Turn off auto leveling for trigger
Sets trigger level to -20.0 dBm
Sets trigger hold-off to 20 ms
Assigns upper window to a single
numeric display
Assigns lower window to a dual numeric
display
Upper window to show average power
using timing defined by gate1
Lower window upper display line to show
peak-to-average ratio using timing
defined by gate1
Lower window lower display line to show
peak power ratio using timing defined by
gate2
Keysight EPM-P Series Programming Guide