Signal analyzer option exm, external mixing upgrade kit (29 pages)
Summary of Contents for Keysight Technologies E5868A
Page 1
E5868A and E5869A Additional Removable Windows 10 SSDs for 1686x-Series Logic Analyzers INSTALLATION AND SETUP GUIDE...
Page 2
WRITTEN AGREEMENT WITH WARRANTY conditions are fully understood and EULA shall apply, except to the extent that TERMS COVERING THE MATERIAL IN THIS met. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Page 3
In Case of Damage Products that appear damaged or defective should be made inoperative and secured against unintended operation. Return the product to a Keysight Sales and Service Office. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Page 4
E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Step 5. Power on the 1686x Logic Analyzer Step 6. Perform the first-time Setup Steps Step 7. Restore Data Step 8. Install any Additional Application Software Resolve any Issues with the Installation E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Page 6
Contents E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Page 7
E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide Overview E5868A and E5869A Additional Removable SSDs / 8 Handling the E5868A and E5869A SSDs / 9...
To ensure that you are using the correct model of removable CAUTION SSD for your 1686x logic analyzer, match the panel color of the additional SSD with the panel color of the SSD you are replacing. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Protect the SSD Against Contamination of the Edge Connector The SSD edge connector is sensitive to ESD and CAUTION mechanical or material contamination. Take precautions to protect the edge connector from contamination during handling and storage. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Page 10
E5868A and E5869A Additional Removable Windows 10 SSDs for 16860-Series Logic Analyzers Installation Guide Installing the Additional Removable SSD Step 1. Back up Data for Transfer to the New SSD / 11 Step 2. Power Down the 1686x Logic Analyzer / 11 Step 3.
Never attempt to remove or install any assembly with the instrument on or with the power cable connected. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Remove the power cord. Step 3. Remove the Currently Installed SSD Loosen both thumb screws that hold the hard disk drive in place. Removable SSD Thumb Screws E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Step 4. Install the New SSD Slide the new SSD into the drive bay. Gently press the drive tray all the way in to seat the disk drive connectors. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Transfer to the New SSD" on page 11. Step 8. Install any Additional Application Software Resolve any Issues with the Installation If you have any questions, go to www.keysight.com/find/contactus help. E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...
Page 15
E5868A and E5869A Additional Removable SSDs for 16860-Series Logic Analyzers Installation Guide...