1. Gaging plastic
2. Scale
5) Remove cap and using scale (2) on gaging plastic (1) envelope,
measure gaging plastic width at its widest point. If clearance ex-
ceeds its limit, replace bearing. Always replace both upper and
lower inserts as a unit.
A new standard bearing may produce proper clearance.
If not, it will be necessary to regrind crankshaft journal for use of
0.25 mm undersize bearing.
After selecting new bearing, recheck clearance.
Bearing clearance
Selection of main bearings
STANDARD BEARING:
If bearing is in malcondition, or bearing clearance is out of specifica-
tion, select a new standard bearing according to following proce-
dure and install it.
1) First check journal diameter by using following procedure.
As shown in figure, crank webs of No.1 cylinder (1) has five
stamped numerals.
Three kinds of numerals ("1", "2" and "3") represent following
journal diameters.
Numeral stamped
The first, second, third and fourth (left to right) stamped numer-
als represent journal diameters at bearing caps "1", "2", "3" and
"4" respectively.
For example, in figure, the first (leftmost) numeral "3" indicates
that journal dia. at bearing cap "1" is within 44.982 – 44.988 mm
(1.7709 – 1.7712 in.), and second one "1" indicates that journal
dia. at cap "2" is within 44.994 – 45.000 mm (1.7714 – 1.7716 in.).
2. Oil pump
Standard
0.020 – 0.040 mm
(0.0008 – 0.0016 in.)
Journal diameter
44.994 – 45.000 mm
1
(1.7714 – 1.7716 in.)
44.988 – 44.994 mm
2
(1.7712 – 1.7714 in.)
44.982 – 44.988 mm
3
(1.7709 – 1.7712 in.)
ENGINE MECHANICAL 6A-67
Limit
0.060 mm
(0.0023 in.)