6A-10 ENGINE MECHANICAL
AIR CLEANER ELEMENT
This air cleaner element is of dry type. Remember that it needs
cleaning according to following procedure.
REMOVAL
1) Disconnect air cleaner outlet No.1 hose from air cleaner assem-
bly (1).
2) Open air cleaner case after unhooking its clamps.
3) Remove air cleaner element from case.
INSPECTION
Check air cleaner element for dirt. Replace excessively dirty ele-
ment.
CLEANING
Blow off dust by compressed air from air outlet side of element.
INSTALLATION
Reverse removal procedure for installation.
AIR CLEANER ASSEMBLY
REMOVAL
1) Disconnect air cleaner outlet hose (1) from air cleaner assembly
(2).
2) Remove suction pipe (3) from air cleaner assembly.
3) Remove air cleaner assembly by removing bolt (4) shown in fig-
ure.
INSTALLATION
Reverse removal procedure for installation, noting the following.
D Install suction pipe grommet (5) in the direction indicated in figure.
D Clamp each hose securely.
A: Air cleaner side
B: Suction pipe side
AIR CLEANER OUTLET HOSE
REMOVAL
1) Disconnect negative cable at battery.
2) Disconnect IAT sensor (1) wire at coupler.
3) Remove air cleaner outlet hose (2).
INSTALLATION
Reverse removal procedure for installation.