Altera Cyclone IV Device Handbook page 477

Table of Contents

Advertisement

Chapter 1: Cyclone IV Device Datasheet
Switching Characteristics
Table 1–34. True LVDS Transmitter Timing Specifications for Cyclone IV Devices
Symbol
Modes
Min
×10
×8
f
(input
×7
HSCLK
clock
×4
frequency)
×2
×1
×10
100
×8
×7
HSIODR
×4
×2
×1
t
DUTY
TCCS
Output jitter
(peak to peak)
(2)
t
LOCK
Notes to
Table
1–34:
(1) Cyclone IV E—true LVDS transmitter is only supported at the output pin of Row I/O Banks 1, 2, 5, and 6.
Cyclone IV GX—true LVDS transmitter is only supported at the output pin of Row I/O Banks 5 and 6.
(2) t
is the time required for the PLL to lock from the end-of-device configuration.
LOCK
(3) Cyclone IV E 1.0 V core voltage devices only support C8L, C9L, and I8L speed grades. Cyclone IV E 1.2 V core voltage devices only support
C6, C7, C8, I7, and A7 speed grades. Cyclone IV GX devices only support C6, C7, C8, and I7 speed grades.
Table 1–35. Emulated LVDS Transmitter Timing Specifications for Cyclone IV Devices
Symbol
Modes
×10
×8
f
(input
×7
HSCLK
clock
×4
frequency)
×2
×1
×10
×8
×7
HSIODR
×4
×2
×1
December 2016 Altera Corporation
C6
C7, I7
Max
Min
Max
5
420
5
370
5
420
5
370
5
420
5
370
5
420
5
370
5
420
5
370
5
420
5
402.5
840
100
740
80
840
80
740
70
840
70
740
40
840
40
740
20
840
20
740
10
420
10
402.5
45
55
45
55
200
200
500
500
1
1
C6
C7, I7
Min
Max
Min
Max
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
402.5
5
402.5
100
640
100
640
80
640
80
640
70
640
70
640
40
640
40
640
20
640
20
640
10
402.5
10
402.5
(1),
(3)
C8, A7
C8L, I8L
Min
Max
Min
Max
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
320
5
402.5
5
362
100
640
100
640
80
640
80
640
70
640
70
640
40
640
40
640
20
640
20
640
10
402.5
10
362
45
55
45
55
200
200
550
600
1
(1),
C8, A7
C8L, I8L
Min
Max
Min
Max
5
275
5
275
5
275
5
275
5
275
5
275
5
275
5
275
5
275
5
275
5
402.5
5
362
100
550
100
550
80
550
80
550
70
550
70
550
40
550
40
550
20
550
20
550
10
402.5
10
362
1–31
C9L
Unit
Min
Max
5
250
MHz
5
250
MHz
5
250
MHz
5
250
MHz
5
250
MHz
5
265
MHz
100
500
Mbps
80
500
Mbps
70
500
Mbps
40
500
Mbps
20
500
Mbps
10
265
Mbps
45
55
%
200
ps
700
ps
1
1
ms
(3)
(Part 1 of 2)
C9L
Unit
Min
Max
5
250
MHz
5
250
MHz
5
250
MHz
5
250
MHz
5
250
MHz
5
265
MHz
100
500
Mbps
80
500
Mbps
70
500
Mbps
40
500
Mbps
20
500
Mbps
10
265
Mbps
Cyclone IV Device Handbook,
Volume 3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cyclone IV and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF