2–16
This solution may violate some of the protocol specific requirements. In such case,
you can use Manual CDR lock option.
For Manual CDR lock mode, rx_freqlocked signal is not available. Upon
detection of a dead link, take the following steps:
a. Switch to LTR mode.
b. Assert rx_digitalreset.
c. Wait for rx_pll_locked to go high.
d. When you detect incoming data on the receive pins, switch to LTD mode.
e. Wait for a duration of t
f. De-assert rx_digitalreset.
Cyclone IV Device Handbook,
Volume 2
LTD_Manual
after the rx_locktodata signal is asserted in manual mode.
Chapter 2: Cyclone IV Reset Control and Power Down
, which is the time taken to recover valid data
September 2014 Altera Corporation
Transceiver Reset Sequences