RUGGEDCOM ROX II
CLI User Guide
Parameter
area-authorization { area-authorization }
area-password { area-password }
area-authentication { area-authentication }
domain-authorization { domain-authorization }
domain-password { domain-password }
domain-authentication { domain-authentication }
4.
Add one or more Network Entity Titles (NETs). For more information, refer to
Network Entity Titles (NETs)"
5.
If necessary, configure intervals for the generation of Link-State Packets (LSPs). The default is 30 seconds.
For more information, refer to
6.
If necessary, configure refresh intervals for Link-State Packets (LSPs). The default is 900 seconds. For more
information, refer to
7.
If necessary, configure the minimum interval between consecutive SPF calculations. The default is 1 second.
For more information, refer to
8.
If necessary, configure how long LSPs can reside in the device's Link State Database (LSDB) before they
are refreshed. The default is 1200 seconds. For more information, refer to
Lifetime of
LSPs".
9.
If necessary, define rules for redistributing static, RIP, BGP or OSPF routes. For more information, refer to
Section 5.18.12, "Managing Redistribution Metrics"
10. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
Section 5.18.5.3

Deleting an Area Tag

To delete an area tag for dynamic IS-IS routes, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the area tag by typing:
no routing isis area name
Where:
Deleting an Area Tag
Section 5.18.7, "Managing LSP
Section 5.18.10, "Managing LSP Refresh
Section 5.18.8, "Managing SPF
Description
Synopsis: { clear, md5 }
Default: clear
The authorization type for the area password. Default is clear.
Synopsis: A string 1 to 254 characters long
The area password to be used for transmission of level-1 LSPs.
Synopsis: { send-only, validate }
Default: send-only
The authentication option to be used with the area password on
SNP PDUs. Default is send-only.
Synopsis: { clear, md5 }
Default: clear
The authorization type for the domain password. Default is clear.
Synopsis: A string 1 to 254 characters long
The domain password to be used for transmission of level-2
LSPs.
Synopsis: { send-only, validate }
Default: send-only
The authentication option to be used with the domain password
on SNP PDUs. Default is send-only.