Chapter 3
Device Management
If no data links have been configured, add data links as needed. For more information, refer to
"Adding a Data
Link".
Section 3.23.14.2

Adding a Data Link

To add a data link for a frame relay connection, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the data link by typing:
interface wan interface protocol channel number connection framerelay dlci id
Where:
• interface is the WAN interface
• protocol is either T1 or E1
• number is the channel number
• id is the ID of the data link
3.
Configure the following parameter(s) as required:
Parameter
on-demand
mtu { mtu }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 3.23.14.3

Deleting a Data Link

To delete a data link for a frame relay connection, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the data link by typing:
no interface wan interface protocol channel number connection framerelay dlci id
Where:
• interface is the WAN interface
• protocol is either T1 or E1
• number is the channel number
• id is the ID of the data link
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
144
Description
Synopsis: typeless
This interface is up or down on demand of link fail over.
Synopsis: An integer between 256 and 1500
Default: 1500
Maximum transmission unit (largest packet size allowed for this
interface).
RUGGEDCOM ROX II
CLI User Guide
Section 3.23.14.2,
Adding a Data Link