Removing A Line Module; Installing A New Line Module; Viewing A List Of Line Module Configurations - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 3
Device Management
Section 3.15.1

Removing a Line Module

To remove a line module from the chassis, do the following:
1.
Shut down the device. The device will shutdown for a period of time before rebooting and restarting. The
default time-out period is 300 seconds (five minutes). If more time is required to complete the procedure,
disconnect power from the device during the time-out period. For more information on how to shutdown the
device, refer to
2.
Remove the line module from the device.
Section 3.15.2

Installing a New Line Module

To install a new line module in the chassis, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Set the module type to none by typing:
chassis line-modules line-module slot module-type type
Where:
• slot is the name of the module location
• type is the module type
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
4.
Shut down the device. The device will shutdown for a period of time before rebooting and restarting. The
default time-out period is 300 seconds (five minutes). If more time is required to complete the procedure,
disconnect power from the device during the time-out period. For more information on how to shutdown the
device, refer to
5.
Insert the new line module into the empty slot in the chassis.
6.
Reboot the device. For more information, refer to
After the device is rebooted, the new line module is automatically detected and operational.
7.
If the line module is different from the previous module installed in the same slot, add a configuration for the
new line module. For more information, refer to
Section 3.15.3

Viewing a List of Line Module Configurations

To view a list of line module configurations, type:
show running-config chassis line-modules
If line modules have been configured, a table or list similar to the following example appears:
ruggedcom# show running-config chassis line-modules | tab
chassis
line-modules
line-module
86
Section 3.4, "Shutting Down the
Section 3.4, "Shutting Down the
Device".
Device".
Section 3.5, "Rebooting the
Section 3.15.4, "Configuring a Line
ADMIN
ADMIN
RUGGEDCOM ROX II
CLI User Guide
Device".
Module".
Removing a Line Module

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rx1500Rx1512Rx1501Rx1510Rx1511

Table of Contents