3.
Configure the following parameter(s) as required:
Parameter
frame { frame }
line-code { line-code }
clock { clock }
lbo { lbo }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 3.23.7

Configuring an E1 Line

To configure E1 parameters for a WAN interface, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Navigate to interface » wan » {interface} » E1, where {interface} is the WAN interface.
3.
Configure the following parameter(s) as required:
Parameter
frame { frame }
line-code { line-code }
clock { clock }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Configuring an E1 Line
Description
Synopsis: { esf }
Default: esf
The frame format.
Synopsis: { b8zs }
Default: b8zs
The line encoding/decoding scheme.
Synopsis: { normal, master }
Default: normal
Serial clocking mode: master or normal. <itemizedlist><listitem>master : provide serial
clock signal.</listitem> <listitem>normal : accept external clock signal.</listitem></
itemizedlist>
Synopsis: { 0db, 7.5db, 15db, 22.5db, 0-110ft, 110-220ft, 220-330ft, 330-440ft,
440-550ft, 550-660ft }
Default: 0db
Line Build Out: tunes the shape of the T1 pulses and adjusts their amplitude depending
upon distances and the desired attenuation.
Description
Synopsis: { ncrc4, crc4 }
Default: ncrc4
The frame format.
Synopsis: { hdb3 }
Default: hdb3
A line encoding/decoding scheme.
Synopsis: { normal, master }
Default: normal
Serial clocking mode: master or normal. <itemizedlist><listitem>master : provide serial
clock signal.</listitem> <listitem>normal : accept external clock signal.</listitem></
itemizedlist>