Section 3.14.2

Adding a Fixed Module Configuration

To add a configuration for a fixed module, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the module by typing:
chassis fixed-modules fixed-module slot
Where:
• slot is the name of the module location
3.
Configure the following parameter(s) as required:
Parameter
module-type { module-type }
partnumber { partnumber }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 3.14.3

Deleting a Fixed Module Configuration

To delete the configuration for a fixed module, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the configuration for a fixed module by typing:
no chassis fixed-modules fixed-module slot
Where:
• slot is the name of the module location
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 3.15

Managing Line Modules

The following sections describe how to properly add, replace and configure line modules:
Section 3.15.1, "Removing a Line Module"
Section 3.15.2, "Installing a New Line Module"
Section 3.15.3, "Viewing a List of Line Module Configurations"
Section 3.15.4, "Configuring a Line Module"
Section 3.15.5, "Enabling/Disabling Controlled Bypass for M12 Line Modules"
Adding a Fixed Module Configuration
Description
Synopsis: A string 1 to 60 characters long
The module type to be used in this slot.
Synopsis: A string 1 to 74 characters long
The part number of the module type in this slot.
Chapter 3
Device Management
85

Advertisement

Table of Contents
loading