Chapter 5
Setup and Configuration
Parameter
interface { interface }
mark { mark }
min-bandwidth { min-bandwidth }
minbw-unit { minbw-unit }
max-bandwidth { max-bandwidth }
maxbw-unit { maxbw-unit }
priority { priority }
description { description }
tos-minimize-delay
tos-maximize-throughput
tos-maximize-reliability
574
Description
Internet protocol type - use both when no addresses are used, otherwise define IPv4
and IPv6 rules for each type of addresses used.
Synopsis: A string
The interface to which this class applies. Each interface must be
listed only once. Lowercase alphanumerical as well as '.' and '-' characters are allowed.
Synopsis: An integer between 1 and 255
A mark that identifies traffic belonging to this class. This is a
unique integer between 1-255. Each class must have its own unique mark.
Synopsis: A string
The minimum bandwidth this class should have when the traffic load rises. This can
be either a numeric value or a calculated expression based on the bandwidth of
the interface. A fixed numerical value must only be a number - its unit is specified
in Minbw-unit. A calculated expression is based on a fraction of the 'full' bandwidth,
such as: <orderedlist><listitem>'full/3' for a third of the bandwidth and</listitem>
<listitem>'full*9/10' for nine tenths of the bandwidth.</listitem></orderedlist> In such a
case, do not specify any minbw-unit.
Synopsis: { none, kilobits, megabits }
Default: none
(per second) Only if the minimum bandwidth is a <emphasis role="bold">single
numerical value</emphasis>
Synopsis: A string
The maximum bandwidth this class is allowed to use when the link is idle. This can
be either a numeric value or a calculated expression based on the bandwidth of the
interface. A fixed numerical value must only be a number - its unit is specified in
Maxbw-unit. A calculated expression is based on a fraction of the 'full' bandwidth,
such as: <orderedlist><listitem>'full/3' for a third of the bandwidth and</listitem>
<listitem>'full*9/10' for nine tenths of the bandwidth.</listitem></orderedlist> In such a
case, do not specify any maxbw-unit.
Synopsis: { none, kilobits, megabits }
Default: none
(per second) only if max-bandwidth is a <emphasis role="bold">single numerical value</
emphasis>
Synopsis: An integer between 0 and 7
Default: 0
The priority in which classes will be serviced. Higher priority
classes will experience less delay since they are serviced
first. Priority values are serviced in ascending order
(e.g. 0 is higher priority than 1. Minimum: 7).
Synopsis: A string
A description for this configuration item.
Synopsis: true or false
Default: false
Value/mask encoding: 0x10/0x10
Synopsis: true or false
Default: false
Value/mask encoding: 0x08/0x08
Synopsis: true or false
Default: false