RUGGEDCOM ROX II
CLI User Guide
IMPORTANT!
When a USB Mass Storage drive is used, do not remove the drive during the file transfer.
NOTE
All parameters are locked during a software upgrade until the device is rebooted and the upgraded
partition is changed to an active state. This prevents post-upgrade configuration changes that are not
carried over to the upgraded partition.
If required, the software upgrade can be stopped/declined at any time before the device is rebooted.
For more information about stopping/declining a software upgrade, refer to
Declining a Software
NOTE
All system configurations and user files (i.e. feature keys, configuration files, etc.) are carried over to
the upgrade partition.
NOTE
If a major system failure is detected upon rebooting with the newly upgraded partition, the device will
automatically roll back to the previously active partition.
To upgrade the RUGGEDCOM ROX II software, do the following:
1.
If the source of the software is a USB Mass Storage drive, insert the drive in the USB port on the device. For
more information, refer to the RUGGEDCOM RX1500/RX1501/RX1510/RX1511/RX1512 Installation Guide.
2.
Make sure the source of the software upgrade has been configured. For more information, refer to
Section 3.11.1, "Configuring the Upgrade
3.
Make sure the CLI is in Configuration mode.
4.
Launch the software upgrade wizard by typing:
wizard rox_upgrade
The wizard will require user input to complete the upgrade. Follow the online instructions.
When the upgrade process begins, the wizard displays the status of the upgrade. For example:
ruggedcom(config)# wizard rox_upgrade
The upgrade repository url is set to: http://rceng03/debianppc/rr2
Press <ENTER> to accept this or type a new address to change it:
The software release you are upgrading to is: rr2
Press <ENTER> to accept this or type a different version:
Checking for a more recent version of the upgrade system
Already running the most recent version of the upgrade system
********************************************************************
Launching ROXII Upgrade.......
Upgrading system to Partition 2
Estimating size of upgrade. This may take a few minutes....
31 packages to install, 20799050 bytes to download
15768 files, 635375611 bytes will be copied to Partition 2
Starting upgrade...
Preparing to transfer files to alternate partition. You may not see activity for a few minutes....
---- File Transfer Phase: 635375611 bytes, 15768 files ----
progress: 100%
Upgrading the RUGGEDCOM ROX II Software
Upgrade".
Source".
Chapter 3
Device Management
Section 3.11.4, "Stopping/
75