Restarting The Serial Server; Resetting A Serial Port - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 3
Device Management
Parameter
alias { alias }
baud-rate { baud-rate }
data-bits { data-bits }
parity { parity }
stop-bits { stop-bits }
flow-control { flow-control }
port-type { port-type }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 3.19.7

Restarting the Serial Server

To restart the serial server, type:
interfaces serial restart-serserver
Section 3.19.8

Resetting a Serial Port

To reset a serial port, type:
interfaces serial port name reset
Where:
• name is the name assigned to the port
110
Description
Provides the option to enable or disable this interface. When
unchecked (i.e disabled), the interface will prevent all frames from
being sent and received on that interface.
Synopsis: A string 1 to 64 characters long
The SNMP alias name of the interface.
Synopsis: { 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200, 230400 }
Default: 9600
The baud rate selection of the serial port.
Synopsis: An integer between 7 and 8
Default: 8
The number of data bits.
Synopsis: { none, even, odd }
Default: none
The parity of the serial port.
Synopsis: An integer between 1 and 2
Default: 1
The number of stop bits of the serial port.
Synopsis: { none, xonxoff }
Default: none
The flow control of the serial port.
Synopsis: { rs232, rs422, rs485 }
Default: rs232
The type of serial port.
RUGGEDCOM ROX II
CLI User Guide
Restarting the Serial Server