4.
Enter the calibration value and run the cable diagnostic test a few more times. The distance to the OPEN
fault should now be similar to the cable length. Use the distance value to determine the calibration value.
For information about how to view the test results, refer to
Section 3.17.8.2

Viewing Cable Diagnostic Statistics

To view the statistics collected for a switched Ethernet port after a cable diagnostic test, type:
show interfaces switch slot port diagnostics cable-diagnostic-results
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
A list similar to the following example appears:
ruggedcom# show interfaces switch lm1 1 diagnostics cable-diagnostic-results
diagnostics cable-diagnostic-results
running
good
open
short
imped
pass fail total "
run count
pass count
fail count
This list provides the following information:
Parameter
running
good
open
short
imped
pass-fail-total
run-count
pass-count
Viewing Cable Diagnostic Statistics
false
20
0
20
0
10/
0/
10
"
0
0
0
Section 3.17.8.2, "Viewing Cable Diagnostic
Description
Synopsis: true or false
Whether or not a cable test is currently running on this port
The number of times GOOD TERMINATION (no fault) is detected on
the cable pairs of the selected port.
The number of times OPEN is detected on the cable pairs of the
selected port.
The number of times SHORT is detected on the cable pairs of the
selected port.
The number of times IMPEDANCE MISMATCH is detected on the
cable pairs of the selected port.
Synopsis: A string 1 to 19 characters long
This field summarizes the results of the cable diagnostics performed
so far. <itemizedlist><listitem>Pass : the number of times cable
diagnostics were successfully completed on the selected port.</
listitem> <listitem>Fail : the number of times cable diagnostics failed
to complete on the selected port.</listitem> <listitem>Total : the
total number of times cable diagnostics have been attempted on the
selected port.</listitem></itemizedlist>
Run Count : The total number of iterations
Pass Count
Chapter 3
Device Management
Statistics".