Parameter
min-rtt
average-rtt
max-rtt
standard-deviation-rtt
Section 3.16.3

Adding an Event Tracker

To add an event tracker, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the event tracker by typing:
global tracking event name
• name is the name of the tracking event
3.
Configure the following parameter(s) as required:
Parameter
target { target }
source-ip { source-ip }
source-interface { source-interface }
timeout { timeout }
interval { interval }
fall { fall }
rise { rise }
state
90
Description
Synopsis: A string
The minimum of the round trip time (in milliseconds).
Synopsis: A string
The average of the round trip time (in milliseconds).
Synopsis: A string
The maximum of the round trip time (in milliseconds).
Synopsis: A string
The standard deviation of the round trip time (in milliseconds).
Description
Synopsis: A string
Configures the ping target as an IPv4 address or
hostname.domain.
Synopsis: A string 7 to 15 characters long or a string 6 to 40
characters long
Sets the source address to a specified IPv4 address.
Forces a ping on a selected interface.
Determines how many milliseconds to wait for the ICMP
response.
Synopsis: A number with a value of 100 or greater
Determines how many milliseconds to wait before sending
another ICMP request.
Synopsis: An integer
The number of times a failure occurs before changing the
tracking state from up to down.
Synopsis: An integer
The number of times success occurs before changing the
tracking state from down to up.
Synopsis: { up, down }
Default: up
The state of the event.