Pre-Configured Alarms; Viewing A List Of Active Alarms - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 4
System Administration
Section 4.6.2, "Viewing a List of Active Alarms"
Section 4.6.3, "Clearing and Acknowledging Alarms"
Section 4.6.4, "Configuring an Alarm"
Section 4.6.1

Pre-Configured Alarms

RUGGEDCOM ROX II is equipped with a series of pre-configured alarms designed to monitor and protect the
device.
Alarm Type
Alarm
Admin
Featurekey mismatch
Featurekey partial mismatch
Chassis
PM1 bad supply
PM2 bad supply (For RX1500 and
RX1510 Only)
PM1 MOV protection bad
PM2 MOV protection bad (For
RX1500 and RX1510 Only)
Real-time clock battery low
LM Watchdog Failure
Module Type Mismatch
Line Module Removed
Line Module Inserted
Section 4.6.2

Viewing a List of Active Alarms

To view a list of alarms for a specific alarm type, type:
162
Description
The featurekey does not match the
serial numbers for the control module
and backplane hardware.
The featurekey does not match the
serial number for either the control
module or backplane hardware.
Input power to the power module is
outside nominal operating range.
Input power to the power module is
outside nominal operating range.
The Metal Oxide Varistor (MOV)
protection component within the PM1
power module is damaged.
The Metal Oxide Varistor (MOV)
protection component within the PM2
power module is damaged.
The Real-Time Clock (RTC) battery in
the control module is depleted.
The specified line module has
stopped sending its heartbeat
message to the control module.
The configured module type does not
match the detected module type.
The specified line module has either
been removed or lost contact with the
chassis.
A new line module has been inserted
in the specified slot.
RUGGEDCOM ROX II
CLI User Guide
Suggested Resolution
Move the featurekey to the correct
device with the matching hardware or
request an updated key from Siemens
Customer Support.
Move the featurekey to the correct
device with the matching hardware or
request an updated key from Siemens
Customer Support.
Make sure the input power operating
range meets the device requirements.
Make sure the input power operating
range meets the device requirements.
Contact Siemens Customer Support
to return the power module.
Contact Siemens Customer Support
to return the power module.
Contact Siemens Customer Support
to return the device for repair.
Inspect the line module to make sure
it is functioning properly.
Updated the chassis configuration or
install the correct module type.
Inspect the line module.
Pre-Configured Alarms