Adding A Static Cross-Connect; Deleting A Static Cross-Connect - Siemens RUGGEDCOM ROX II User Manual

Cli
Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 5
Setup and Configuration
If no static cross-connects have been configured, add cross-connects as needed. For more information about
adding static cross-connects, refer to
Section 5.41.6.3

Adding a Static Cross-Connect

To add a static cross-connect, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add a static cross-connect by typing:
mpls static-mpls crossconnect in-label in-label
Where:
• in-label is the incoming label
3.
Configure the following parameter(s) as required:
Parameter
out-interface { out-interface }
next-hop { next-hop }
out-label { out-label }
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 5.41.6.4

Deleting a Static Cross-Connect

To delete a static cross-connect, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete a static cross-connect by typing:
no mpls static-mpls crossconnect in-label in-label
Where:
• in-label is the incoming label
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
606
Section 5.41.6.3, "Adding a Static
Description
The outgoing interface.
Synopsis: A string 7 to 15 characters long or a string 6 to 40
characters long
The destination next-hop router (IPv4 or IPv6 format).
Synopsis: { explicit-null, implicit-null } or an integer between 16
and 1048575
The outgoing label: 'explicit-null', 'implicit-null' or integer 16 ->
1048575.
Cross-Connect".
Adding a Static Cross-Connect
RUGGEDCOM ROX II
CLI User Guide