sets the limits an equal amount above and below a specified
middle value, instead of setting upper and lower limits
to set limits for testing a device that is
ii . . . . . i . . / . : . . : . : : . . . .. . . . . .
specified at a particular value plus or minus an equal tolerance.
For example, a device may be specified at 0 dB f3 dB. Enter
the delta limits as 3 dB and the middle value as 0 dl3.
(Option 010 only) amplitude demodulation for CW time
transform measurements
(Option 010 only) turns time domain demodulation off.
(Option 010 only) phase demodulation for CW TIME transform
measurements
lets you specify the number of directory llles to be initialized
on a disk. This is particularly useful with a hard disk, where
you may want a directory larger than the default 256 files, or
with a floppy disk you may want to reduce the directory to
allow extra space for data tiles The number of directory flies
must be a multiple of 8. The minimum number is 8, and there
is no practical maximum limit. Set the directory size before
specifies the number of the disk unit in the disk drive that is to
be accessed in an external disk store or load routine. This is
used in conjunction with the HP-IB address of the disk drive,
and the volume number, to gain access to a specilIc area on a
disk. The access hierarchy is HP-IB address, disk unit number,
disk volume number.
displays response and stimulus values for ail markers that are
turned on. Available only if no marker functions are on.
provides access to a series of menus for instrument and active
channel display functions The hrst menu deties the displayed
active channel trace in terms of the mathematical relationship
between data and trace memory. Other functions include dual
channel display (overlaid or split), display intensity, color
selection, active channel display title, and frequency blanking.
displays the current measurement data for the active channel.
leads to a series of service tests for the display.
activates both forward and reverse calibration measurements
from selected calibration menus.
has two functions:
It shows the current sequences in memory. 'lb run a
n
sequence, press the softkey next to the desired sequence title.
When entered into a sequence, this command performs a
n
one-way jump to the sequence residing in the specified
sequence position (SEQUENCE 1 through 6). ~~~~~~~~~~
jumps to a softkey position, not to a specillc sequence title.
Whatever sequence is in the selected softkey position will
. . . . . . , . . . . . . . . . . . . , . , . . . . . A . .