Agilent Technologies 8720E Series Configuration Manual

Network analyzers, 50 mhz to 13.5/20/40/13.5 ghz

Advertisement

Quick Links

Discontinued Product Information
- For Support Reference Only -
Information herein, may refer to products/services no longer supported.
We regret any inconvenience caused by obsolete information. For the
latest information on Agilent's test and measurement products go to:
www.agilent.com/find/products
In the US, call Agilent Technologies at 1-800-829-4444
(any weekday between 8am-5pm in any U.S. time zone)
World-wide Agilent sales office contact information is available at:
www.agilent.com/find/contactus
Agilent 8720E Family
Network Analyzers
Configuration Guide
8719ET, 50 MHz to 13.5 GHz
8720ET, 50 MHz to 20 GHz
8722ET, 50 MHz to 40 GHz
8719ES, 50 MHz to 13.5 GHz
8720ES, 50 MHz to 20 GHz
8722ES, 50 MHz to 40 GHz
The Agilent Technologies 8720E family of microwave
network analyzers integrates a microwave source,
tuned-receiver, and transmission/reflection or
S-parameter test set into a single, cost-effective
instrument. To complete a microwave measurement
system, select the desired network analyzer options,
test port cables, and calibration kits. Also, addi-
tional measurement accessories may be selected.

Table of Contents

2
2
3
4
4
4
4
4
5
6
6
7
7
7
8
9
10
10
11
Upgrades
12
Application and Product Notes

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies 8720E Series

  • Page 1: Table Of Contents

    In the US, call Agilent Technologies at 1-800-829-4444 S-parameter test set into a single, cost-effective (any weekday between 8am–5pm in any U.S. time zone) instrument. To complete a microwave measurement...
  • Page 2: Transmission/Reflection Network Analyzers

    Transmission/Reflection S-parameter Network Analyzers Network Analyzers 8719ET vector network analyzer, 8719ES vector network analyzer, 50 MHz to 13.5 GHz 50 MHz to 13.5 GHz 8720ET vector network analyzer, 8720ES vector network analyzer, 50 MHz to 20 GHz 50 MHz to 20 GHz 8722ET vector network analyzer, 8722ES vector network analyzer, 50 MHz to 40 GHz...
  • Page 3: Network Analyzer Options

    Network Analyzer Options S-parameter analyzer options The following options apply to both ET and ES models: Some ES options cannot be ordered with other options. See option compatibility table below. Hardware options 007 mechanical transfer switch: replaces the solid- 1CM adds rack mount flange kit for use without state transfer switch with a mechanical trans- handles fer switch.
  • Page 4: Measurement Accessories

    Measurement Accessories Accessories are available in these connector types: Verification kits 7 mm, K-connector (2.92 mm), Type-N, 3.5 mm All Agilent verification kits include: (SMA-compatible), 2.4 mm coaxial, 7-16, WR-90 • precision Z airline (X Band), WR-62 (P Band), WR-42 (K Band), •...
  • Page 5: For Devices With 3.5 Mm Or Sma Connectors

    For devices with 3.5 mm or SMA connectors Electronic calibration kits 85093B RF ECal: 30 kHz to 9 GHz. Includes: Calibration kits 85093-60005 3.5 mm (f) to 3.5 mm (m) RF ECal module 85052B standard: 0.045 to 26.5 GHz. Includes: Option 00M substitutes: 00902-60003 3.5 mm (m) fixed load 85093-60006 3.5 mm (m) to 3.5 mm (m) RF ECal...
  • Page 6: For Devices With 7 Mm Connectors

    Measurement Accessories, continued For devices with 7 mm connectors For devices with Type-N connectors Calibration kits Calibration kits 85050B standard: 0.045 to 18 GHz. Includes: 85054B standard: 0.045 to 18 GHz. Includes: 00909-60008 7 mm coax termination 00909-60011 Type-N (m) fixed lowband load 85050-60006 7 mm fixed broadband load 00909-60012 Type-N (f) fixed lowband load 85050-80007 7 mm short...
  • Page 7: For Devices With 2.4 Mm Connectors

    Verification kit For devices with K connectors (2.92 mm) 85055A 8719/8720 only: 0.045 to 18 GHz Calibration kit Option 1BP MIL-STD 45662A calibration certificate 85056K economy, 2.92/2.4 mm: 0.045 to 40 GHz. with test data Includes: 00901-60003 2.4 mm (m) fixed broadband load Cables 00901-60004 2.4 mm (f) fixed broadband load Use the test port cables recommended for devices...
  • Page 8: For Devices With Waveguide

    Measurement Accessories, continued 85038M economy: 30 kHz to 7.5 GHz. Includes: P Band 85038-80003 7-16 (m) open P11644A calibration kit (standard, WR-62, 12.4 to 85038-80005 7-16 (m) short 18 GHz). Includes: 85038-80007 7-16 (m) fixed load 00896-60007 P-band standard section 11906-80015 7-16 (m) to 7-16 (m) adapter 00910-60002 P-band termination 11644-20017 P-band short...
  • Page 9: Test Configuration Accessories

    Test Configuration Accessories Power meters Bias supplies E4418B EPM series, single channel 6626A precision DC power supply; 2 A, 50 V maximum E4419B EPM series, dual channel 6629A quad-out precision GPIB DC power supply 4142B modular DC source/monitor; 10 A, 200 V maximum Power sensors 8481B 10 MHz to 18 GHz, Type-N (m), 25 watt...
  • Page 10: Peripheral Accessories

    08720-90397. Includes service guide on CD-ROM, 1540-1695 operating case part number 08720-90419. 9211-2657 transit case Computers Any computer configured with a GPIB interface card and software drivers Monitors Any VGA-compatible monitor 1. The 8720E series of network analyzers is supplied with handles.
  • Page 11 Agilent 8719D, 8720D, and 8722D analyzers can be upgraded to have their firmware include the new Options may be added to an Agilent 8720E series net- features introduced in the ES models with one of work analyzer after initial purchase by ordering the the following upgrades.
  • Page 12 Application and Product Notes Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing Pub. Number your risk and problems. We strive to ensure that you get the test and measure-...

This manual is also suitable for:

8719et8722es8720es8720et8722et8719es

Table of Contents