Item
Counter Poller
Interval
Configuration | RingV2
This page provides Ring related configuration.
Item
The group index. This parameter is used for easy identifying the ring when you configure it.
•
Group 1 (Index 1) - It supports configuration of ring.
Index
•
Group 2 (Index 2) - It supports configuration of ring, coupling and dual-homing.
•
Group 3 (Index 3) - It supports configuration of chain and balancing-chain.
Enable Ring on the specific group.
•
When Group 1 or 2 is enabled, all configuration of Group 3 are reset to default. Group 3 all
configuration options are locked.
Mode
•
To configure Group 3, both Group1 and 2 should be disabled first. When Group 3 is
enabled, all configuration of Group1 and 2 are reset to default. Group 1 and 2 all
configuration options are locked.
RocketLinx MP1204-XT User Guide: 2000644 Rev. A
With counter polling enabled, this specifies the interval - in seconds - between
counter poller samples.
Configuration | sFlow (Continued)
Configuration | RingV2
Configuration | RingV2