Comtrol RocketLinx MP1204-XT User Manual page 113

Industrial poe managed switch 8 - gigabit copper ports 4 - gigabit sfp ports
Table of Contents

Advertisement

Item
Controls whether a port explicitly configured as Edge disables itself upon reception of a
Edge Port BPDU
BPDU. The port enters the error-disabled state, and is removed from the active
Guard
topology.
Controls whether a port in the error-disabled state automatically is enabled after a
Port Error
certain time. If recovery is not enabled, ports have to be disabled and re-enabled for
Recovery
normal STP operation. The condition is also cleared by a system reboot.
Port Error
The time to pass before a port in the error-disabled state can be enabled. Valid values
Recovery
are between 30 and 86400 seconds (24 hours).
Timeout
RocketLinx MP1204-XT User Guide: 2000644 Rev. A