Rmon Alarm - Comtrol RocketLinx MP1204-XT User Manual

Industrial poe managed switch 8 - gigabit copper ports 4 - gigabit sfp ports
Table of Contents

Advertisement

rmon alarm

Description RMON Alarm
rmon alarm <id> <oid_str> <interval> { absolute | delta } rising-threshold
Syntax
<rising_threshold> [ <rising_event_id> ] falling-threshold <falling_threshold> [
<falling_event_id> ] { [ rising | falling | both ] }
Name
id
ifInDiscards
fInErrors
ifInNUcastPkts
ifInOctets
ifInUcastPkts
ifInUnknownProtos
ifOutDiscards
ifOutErrors
Parameters
ifOutNUcastPkts
ifOutOctets
ifOutUcastPkts
interval
absolute
delta
rising_threshold
rising_event_id
falling_threshold
falling_event_id
both
falling
rising
RocketLinx MP1204-XT User Guide: 2000644 Rev. A
Description
Alarm entry ID
The number of inbound packets that are discarded even the packets
are normal
The number of inbound packets that contained errors preventing
them from being deliverable to a higher-layer protocol
The number of broad-cast and multi-cast packets delivered to a
higher-layer protocol
The total number of octets received on the interface, including
framing characters
The number of uni-cast packets delivered to a higher-layer protocol
The number of the inbound packets that were discarded because of
the unknown or un-support protocol
The number of outbound packets that are discarded event the packets
is normal
The The number of outbound packets that could not be transmitted
because of errors
The number of broad-cast and multi-cast packets that request to
transmit
The number of octets transmitted out of the interface, including
framing characters
The number of uni-cast packets that request to transmit
Sample interval
Test each sample directly
Test delta between samples
<-2147483648-2147483647> rising threshold value
<0-65535> Event to fire on rising threshold crossing
<-2147483648-2147483647> falling threshold value
<0-65535> Event to fire on falling threshold crossing
Trigger alarm when the first value is larger than the rising threshold
or less than the falling threshold (default)
rigger alarm when the first value is less than the falling threshold
Trigger alarm when the first value is larger than the rising threshold
Configure Mode Commands
Command Line Interface (CLI) - 317

Advertisement

Table of Contents
loading

Table of Contents