Reception - Renesas M16C/6NK Hardware Manual

16-bit single-chip microcomputer m16c family / m16c/60 series
Table of Contents

Advertisement

Under development
This document is under development and its contents are subject to change.
M16C/6N Group (M16C/6NK, M16C/6NM)

19.15.1 Reception

Figure 19.20 shows the behavior of the module when receiving two consecutive CAN messages, that fit
into the slot of the shown CiMCTLj register (i = 0, 1, j = 0 to 15) and leads to losing/overwriting of the first
message.
CANbus
RecReq bit
InvalData bit
NewData bit
MsgLost bit
CANi Successful
Reception Interrupt
RecState bit
RecSucc bit
MBOX bit
i = 0, 1
j = 0 to 15
Figure 19.20 Timing of Receive Data Frame Sequence
(1) On monitoring a SOF on the CAN bus the RecState bit in the CiSTR register becomes "1" (CAN
module is receiver) immediately, given the module has no transmission pending.
(2) After successful reception of the message, the NewData bit in the CiMCTLj register of the receiving
slot becomes "1" (stored new data in slot). The InvalData bit in the CiMCTLj register becomes "1"
(message is being updated) at the same time and the InvalData bit becomes "0" (message is valid)
again after the complete message was transferred to the slot.
(3) When the interrupt enable bit in the CiICR register of the receiving slot = 1 (interrupt enabled), the
CANi successful reception interrupt request is generated and the MBOX bit in the CiSTR register is
changed. It shows the slot number where the message was stored and the RecSucc bit in the CiSTR
register is active.
(4) Read the message out of the slot after setting the New Data bit to "0" (the content of the slot is read or
still under processing by the CPU) by a program.
(5) When next CAN message is received before the the NewData bit is set to "0" by a program or a
receive request to a slot is canceled, the MsgLost bit in the CiMCTLj register is set to "1" (message
has been overwritten). The new received message is transferred to the slot. Generating of an interrupt
request and change of the CiSTR register are same as in 3).
Rev.2.00
Nov 28, 2005
REJ09B0124-0200
SOF
(1)
page 244 of 378
ACK
EOF
IFS
SOF
(2)
(2)
(4)
(3)
Receive slot No.
19. CAN Module
ACK
EOF
IFS
(5)
(5)
(5)

Advertisement