Error Codes - Datalogic Magellan 3450VSi Product Reference Manual

Omni-directional imaging scanner
Table of Contents

Advertisement

Error Codes

If an error is detected, the scanner will sound a long low tone (for three sec-
onds) and flash its LED, indicating a failure. When this occurs, press the Scanner
Pushbutton to hear the error code. If it is configured to do so, the scanner will
sound a series of beeps corresponding to the error code and/or flash its LED
simultaneous to the beeps. The table below describes what these codes mean
and what action should be taken for each.
NUMBER OF
LED
FLASHES/
BEEPS
1
2
6
10
12
13
14
Product Reference Guide
ERROR
Configuration
Interface PCB
Main PCB
Button Error
Imager Module
Software ID Failure
Software Fatal Fault
CORRECTIVE ACTION
Contact Helpdesk for assistance