RS-232 Interface Features

RS-232 ACK NAK Timeout Value

This item specifies the time the scanner will wait for an ACK character from the
host following a label transmission.
To set the ACK NAK Timeout Value:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code below,
3. Scan the appropriate digits from the
The scanner will automatically exit Programming Mode when the appropriate
amount of digits have been scanned.
DEFAULT
Product Reference Guide
0 = Infinite timeout
1 - 75 = Timeout in 200-millisecond increments
to cover any unused bar codes on this and the facing page to ensure that
the scanner reads only the bar code you intend to scan.
that represent the desired timeout. A setting of 0 specifies an infinite tim-
eout. The remaining selectable range is 1-75, which is the timeout in 200-
millisecond increments. Pad all single digit numbers with a leading zero to
yield a two-digit entry (00-75).
Examples:
00 = Infinite timeout
01 = 200ms
05 = 1,000ms (1 second)
40 = 8,000ms (8 seconds)
75 = 15,000ms (15 seconds)
Enter/Exit Programming Mode
Set RS-232 ACK NAK Timeout
Alpha-Numeric Keypad in Appendix C
0606(CR)
Set RS-232 ACK NAK Timeout Value
Default setting for this feature is:
Value. You'll need
01 - 200ms
73