Msi Check Character Calculation - Datalogic Magellan 3450VSi Product Reference Manual

Omni-directional imaging scanner
Table of Contents

Advertisement

Enter/Exit Programming Mode

MSI Check Character Calculation

Enables/disables calculation and verification of optional MSI check characters.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan either the enable or disable bar code below. You'll need to cover any
3. Complete the programming sequence by scanning the ENTER/EXIT Pro-
021601(CR)
MSI Check Character Calculation = Enable
238
If check character calculation is disabled, the risk is increased that
a misread can occur. When disabled, any check characters in a bar
code are treated as data characters.
NOTE
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
gramming Mode bar code.
021600(CR)
MSI Check Character Calculation = Disable
DEFAULT
MSI
Magellan™ 3450VSi

Hide quick links: