Quiet Interval

This setting specifies the amount of time to monitor for keyboard activity
before breaking the keyboard connection.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code below,
3. Scan the appropriate digits from the
4. The scanner will automatically exit Programming Mode when the appro-
DEFAULT
94
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
that represent the desired time interval. The selectable range is 001-100,
which is the interval in 10-millisecond increments. Pad all single and dou-
ble digit numbers with leading zeroes to yield a three-digit entry (001-
100).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
100 = 1,000ms (1 second)
priate amount of digits have been scanned
Set Quiet
Interval. You'll need to cover any
Alpha-Numeric Keypad in Appendix C
.
0303(CR)
Set Quiet Interval
Default setting for this feature is:
00A - 100ms