Good Read Beep Length - Datalogic Magellan 3450VSi Product Reference Manual

Omni-directional imaging scanner
Table of Contents

Advertisement

Enter/Exit Programming Mode

Good Read Beep Length

Specifies the duration of a good read beep.
To set this feature:
1. Scan the Enter/Exit Programming Mode bar code.
2. Scan the bar code,
3. Scan the appropriate digits from the
4. The scanner will automatically exit Programming Mode when the appro-
DEFAULT
30
Set Good Read Beep Length on page
cover any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
that represent the desired good read beep length setting. The selectable
range is 1-255, which is the timeout in 10-millisecond increments. Times
have a tolerance of +/-25%. Pad all single and double digit numbers with
leading zeroes to yield a three-digit entry (001-255).
Examples:
001 = 10ms
005 = 50ms
040 = 400ms
priate amount of digits have been scanned
Good Read Beep Length
Alpha-Numeric Keypad in Appendix C
.
0016(CR)
Set Good Read Beep Length
Default setting for this feature is:
008 - 80ms
30. You'll need to