MSI Minimum Read

MSI Minimum Read
This feature specifies the minimum number of consecutive MSI decodes before
is accepted as good read.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan your selection from the bar codes below. You'll need to cover any
3. Complete the programming sequence by scanning the ENTER/EXIT Pro-
DEFAULT
00BF02(CR)
MSI Minimum Read = 2
00BF04(CR)
MSI Minimum Read = 4
Product Reference Guide
unused bar codes on this and the facing page to ensure that the scanner
reads only the bar code you intend to scan.
gramming Mode bar code.
Enter/Exit Programming Mode
00BF01(CR)
MSI Minimum Read = 1
00BF03(CR)
MSI Minimum Read = 3
241