Enter/Exit Programming Mode

MSI Length 1

If MSI Length Control is set to Fixed-Length decoding, this feature specifies MSI
first fixed length. If MSI Length Control is set to Variable-Length decoding, this
feature specifies the minimum label length.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the bar code,
3. Scan the appropriate digits from the
4. Complete the programming sequence by scanning the ENTER/EXIT Pro-
DEFAULT
244
Set MSI Length 1 on page 244
cover any unused bar codes on this and the facing page to ensure that the
scanner reads only the bar code you intend to scan.
that represent the desired label length. The selectable range for this
option is 4 to 16. Pad all single digit numbers with a leading zero to yield a
two-digit entry (04-16).
gramming Mode bar code.
below. You'll need to
Alpha-Numeric Keypad in Appendix C
00CB(CR)
Set MSI Length 1
Default setting for this feature = 04