Standard 2 of 5 Length 1
If Standard 2 of 5 Length Control is set to Fixed-Length decoding, this feature
specifies Standard 2 of 5 first fixed length. If Standard 2of 5 Length Control is
set to Variable-Length decoding, this feature specifies the minimum label
length.
To set this feature:
1. Scan the ENTER/EXIT Programming Mode bar code.
2. Scan the bar code,
3. Scan the appropriate digits from the
4. Complete the programming sequence by scanning the ENTER/EXIT Pro-
DEFAULT
Product Reference Guide
Set Standard 2 of 5 Length 1 on page 253
need to cover any unused bar codes on this and the facing page to ensure
that the scanner reads only the bar code you intend to scan.
that represent the desired label length. The selectable range for this
option is 1 to 50. Pad all single digit numbers with a leading zero to yield a
two-digit entry (01-50).
gramming Mode bar code.
Enter/Exit Programming Mode
Alpha-Numeric Keypad in Appendix C
0498(CR)
Set Standard 2 of 5 Length 1
Default setting for this feature = 08