Siemens SIMOVERT MASTERDRIVES Manual page 899

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Engineering Information
P
Lifting
Mot
4.97 kW
3.44 kW
1.91 kW
0.6 s
0.3 s
-1.22 kW
-2.52 kW
-3.81 kW
11-42
0.6 s
Negative area corresponds to regenerative
operation
7 s
Fig. 11-22
Curve of motor power output for lifting and lowering
♦ The maximum DC link current during motor operation during
acceleration upwards is as follows:
=
I
Link Inv
max
η
Mot
4970
=
0 89 0 98 135 400
.
.
.
♦ The mean power output of the motor during motor operation is
calculated from the positive characteristic of the motor power output
as follows:
P
Mot A
=
P
Mot mean
1
+
4 97 0 6 3 44 0 3
.
.
.
2
=
♦ The mean DC link current is therefore:
P
=
I
Link mean
η
η
Mot
442
=
0 89 0 98 135 400
.
.
.
Lowering
0.6 s
0.3 s
P
Mot
max
η
135
.
U
Inv
Line
=
10 55
.
A
+
P
Mot E
t
i
2
T
1
+
.
191 0 6
.
.
2
=
0 442
.
7
Mot mean
135
.
U
Inv
Line
=
0 938
.
A
6SE7087-6QX70 (Version AE)
Compendium Motion Control
06.2005
0.6 s
t
kW
Siemens AG
SIMOVERT MASTERDRIVES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents