Parameter
Description
P299*
Service parameter, only for Siemens service personnel.
FieldWeakDir
This parameter is for special applications ONLY and must
not be changed for standard operation.
299
Motor speed at which field weakening is applied for
synchronous machines.
In function diagram: 389.2
P300*
Service parameter, only for Siemens service personnel.
SelectFieldWeak
DANGER: This parameter is for special applications
ONLY and must not be changed for standard operation.
300
Additional protective measures (overvoltage protection)
are required for operating synchronous machines during
field weakening.
Selection of field weakening for synchronous machines
In function diagram: 389.4
P301
Function parameter for setting the smoothing time
Smooth Psi(act)
constant for the rotor flux actual value in the EMF model.
301
Precondition:
P296=3 (ASM field weakening)
If the parameter is set to 0 an automatic adjustment of the
smoothing value takes place.
P307
BICO parameter for selecting the binector from which the
SrcEn HC
command to enable the harmonic compensation function
is given.
307
P308*
Parameter contains the connector for the input signal of
SrcAngleHC
harmonic compensation. Usually this parameter is
interconnected with the mechanical (KK0090) or electrical
308
KK0186) angle.
If the parameter is connected to the fixed connector
K0000, harmonic compensation is deactivated.
P309
Function parameter for entering the harmonic in the motor
HC Harmonic
torque to be compensated for.
309
With P309=0 compensation is deenergized.
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 12000
+ Motor/encoder
Unit: 1/min
+ Motor data
Indices: -
- Drive setting
Type: O2
- Upread/free access
Changeable in:
- Drive setting
Init: 0
Menus:
Min: 0
- Parameter menu
Max: 1
+ Control/gating unit
Unit: -
+ Current control
Indices: -
- Drive setting
Type: O2
- Upread/free access
Changeable in:
- Drive setting
Init: 0,0
Menus:
Min: 0,0
- Parameter menu
Max: 200,0
+ Control/gating unit
Unit: ms
+ Speed control
Indices: -
- Upread/free access
Type: O2
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
Type: L2 ,B
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Control/gating unit
Type: L2 ,K
+ Speed control
,K
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
- Operation enabled
index1: 1
Menus:
Min: 1
- Parameter menu
Max: 12
+ Control/gating unit
Unit: -
+ Speed control
Indices: 2
- Drive setting
Type: O2
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
- Operation enabled
46