Src Setp
P790 (150)
K
+
Src ActV
P791 (91)
K
Src Comp ActV
P795 (91)
K
Src OFF ActV
P799 (91)
K
Src Speed Setp
P802 (150)
K
1
2
Messages
Perm Deviation
0.0 ... 200.0 %
P792.F (3.0)
1
0
P793.F (2.0)
0.0 ... 200.0 %
Set/Act Hyst
Compare Value
0.0 ... 200.0 %
P796.F (100.0)
P797.F (3.0)
OFF Value
0.0 ... 200.0 %
0.0 ... 200.0 %
Compare Hyst
P800.F (0.5)
1
0
OFF1 or OFF3
from sequence control
1
Positive speed setpoint
to status word 1, bit 14 [200.2]
0
3
4
Deviation Time
0.0 ... 100.0 s
(Is only calculated in OFF1, OFF3, OPERATION
P794.F (3.0)
No Set/Act deviation
0
T
to status word 1, bit 8 [200.2]
A034
Set/Act deviation
OFF Delay
Compare Time
0.0 ... 100.0 s
P798.F (3.0)
1
0
T
Comparison value reached
to status word 1, bit 10 [200.2]
0
OFF Delay
No brake
(P605 = 0)
Pulse disable
and brake [470.8]
<1>
OFF Time
0.00 ... 100.00 s
P801.F (0.00)
T
0
Delay
[320.7]
OFF&ActV
n(max, REV Spd)
B409
Src Speed ActV
P803 (91)
K
5
6
V2.4
fp_mc_480_e.vsd
30.08.01
AND MOTID)
<1>
WARNING
If OFF3 is used, the turn-off time
P801 = 0.0 must be set
Gating pulse disable
[320.7]
n(max, REV Spd
A033: Overspeed
1
Overspeed
to status word 2, bit 18 [210.2]
0
7
Function diagram
MASTERDRIVES MC
n959.60 = 4
8
- 480 -