Siemens SIMOVERT MASTERDRIVES Manual page 979

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

n/f(act) speed conditioning (KK0091)
[500.4]
2 % n-ref
1
Isq(act)
[390.4]
0
T = 16 x Tab
n(act)
[500.5]
T = 16 x Tab
The circuit checks whether the specified direction of acceleration
matches the direction of acceleration of the drive
Setpoint/actual deviation
Status word 1, bit 8 [200.2]
n-controller output in limitation [370.8]
1
2
Protective functions
Part 3 (blocking protection)
1 = Setpoint acceleration negative
0 = Setpoint acceleration positive
1
d
1 = Actual acceleration negative
dt
0 = Actual acceleration positive
0
0.2 %
3
Fct Stall/Overload
0 ... 2
P806 (0)
P806:
2
0
1
0
4
5
V2.4
2: De-energized
1: Only stall protection
0: Stall and overload protection
Master/slave drive
Control word 2 [190.5]
1
0
T
0
0
Output deceleration
15 x Tab
0
T
P805 (50.00)
0.00 ... 100.00 s
Stall/Block Time
6
7
Function diagram
fp_mc_492_e.vsd
MASTERDRIVES MC
08.01.02
n957.72 = 6
Alarm A042
Motor stalled
Fault F015
Motor stalled
To status word 2 Bit2
[210.2]
8
- 492 -

Hide quick links: