Parameter
Description
P648*
Function parameter for configuring digital input 5.
Conf DigIn5
0 = Use as a normal digital input
648
1 = OFF2 with rising edge
2 = OFF2 with falling edge
3 = Adopt measured value of the position with rising edge
4 = Adopt measured value of the position with falling edge
5 = Adopt measured value depending on binector
P649*
If parameter value 5 is set in parameter P647/648, then
S.Conf DigIn5
this binector is used to change the transfer of the position
measurement between rising and falling edge.
649
Index 1: enable/disable position measurement recording
Index 2: selection of edge
If the binector has the value 0, the position measurement
is taken on a rising edge.
If the binector has the value 1, the position measurement
is taken on a falling edge.
P651*
BICO parameter for selecting the binector whose value is
S.DigOut1
to be output at terminal -X101/3 of the terminal strip for
the basic unit. In order to use terminal -X101/3 as a digital
651
input, both indices must be set to 0.
P652*
BICO parameter for selecting the binector whose value is
S.DigOut2
to be output at terminal -X101/4 of the terminal strip for
the basic unit. In order to use terminal -X101/4 as a digital
652
input, both indices must be set to 0.
P653*
BICO parameter for selecting the binector whose value is
S.DigOut3
to be output at terminal -X101/5 of the terminal strip for
the basic unit. In order to use terminal -X101/5 as a digital
653
input, both indices must be set to 0.
P654*
BICO parameter for selecting the binector whose value is
S.DigOut4
to be output at terminal -X101/6 of the terminal strip for
the basic unit. In order to use terminal -X101/6 as a digital
654
input, both indices must be set to 0.
P655*
Parameter for selection of the signal type for analog input
EB1 Signal Type
1 on EB1.
0 = +/- 10 V
655
1 = +/- 20 mA
Index 1: AI1 of the first inserted EB1
Index 4: AI1 of the second inserted EB1
Index 2, 3, 5 and 6: no significance
P656*
Parameter for normalization of the analog inputs on EB1.
EB1 AnaInNorm
Incoming signals are multiplied by the entered parameter
value.
656
Index 1 to 3: AI1 to AI3 of the first inserted EB1
Index 4 to 6: AI1 to AI3 of the second inserted EB1
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 5
+ Terminals
Unit: -
- Upread/free access
Indices: 2
Changeable in:
,BDS
- Ready to switch on
Type: O2
index1: 1
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Terminals
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Terminals
,BDS
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Terminals
,BDS
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Terminals
,BDS
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Terminals
,BDS
- Upread/free access
Type: L2 ,B
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 1
+ Terminals
Unit: -
- Upread/free access
Indices: 6
Changeable in:
Type: O2
- Ready to switch on
index1: 1,00
Menus:
Min: 0,00
- Parameter menu
Max: 100,00
+ Terminals
Unit: -
- Upread/free access
Indices: 6
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
79