Siemens SIMOVERT MASTERDRIVES Manual page 1287

Motion control
Hide thumbs Also See for SIMOVERT MASTERDRIVES:
Table of Contents

Advertisement

Parameter
Description
U443*
Parameter for selecting 32-bit connectors for the shift
S.Shift32
multipliers/dividers (2-word)
Index 1: 1st shift multiplier/divider
2443
Index 2: 2nd shift multiplier/divider
Index 3: 3rd shift multiplier/divider
Index 4: 4th shift multiplier/divider
U444*
BICO parameter for selecting the connector whose value
S.ConnToPar V
is to be stored on the parameter.
Only connectors of the basic unit are permissible.
2444
IMPORTANT.
If there is a change of softwiring during the "Operation"
drive state, the trigger condition must always be softwired
and be at 0, as otherwise unintentional parameter
changes may occur.
U445*
Function parameter whose value contains the parameter
ConnToPar Par#
number for the connector-to-parameter converter.
Only parameters of the basic unit are permissible.
2445
0 = no parameter selected.
U446*
Function parameter whose value contains the index of the
ConnToPar Index
parameter for the connector-to- parameter converter.
0 = no index parameter.
2446
U447*
BICO parameter for selecting the binector for the trigger
S.ConnToPar Trg
signal which results in storage of the connector value on
the parameter.
2447
IMPORTANT:
If the softwiring is changed during the "Operation" drive
status, the trigger condition must always be softwired and
be at 0, as otherwise unintentional parameter changes
may occur.
U448*
BICO parameter for selecting the binector which
S.ConnToParEEPR
determines the memory area for the connector-to-
parameter conversion.
2448
0 = RAM
1 = EEPROM
IMPORTANT.
If the EEPROM is continually written with different values,
this will reduce the service life of the component.
U449*
BICO parameter for selecting the binector which
S.ParToConnRd
determines the type of access for the connector-to-
parameter conversion.
2449
0 = write
1 = read
n450
The parameter shows the status of the synchronous
CycleSetp.Synch
running status signals
2450
Index 1: Low word of the synchronous running status
signal
Index 2: High word of the synchronous running status
signal
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 4
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 5
+ Free blocks
Type: L2 ,K
- Upread/free access
,K
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 2999
+ Free blocks
Unit: -
- Upread/free access
Indices: 5
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Min: 0
- Parameter menu
Max: 255
+ Free blocks
Unit: -
- Upread/free access
Indices: 5
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 5
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 5
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
index1: 0
Menus:
Unit: -
- Parameter menu
Indices: 5
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 0
Menus:
Unit: -
- Parameter menu
Indices: 2
+ Technology
Type: V2
+ Synchronism
- Upread/free access
170

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents