Bit No.
from sequence control 1)
Bit 0
from sequence control 1)
Bit 1
from sequence control 1)
Bit 2
from sequence control 1)
Bit 3
from sequence control 1)
Bit 4
from sequence control 1)
Bit 5
from sequence control 1)
Bit 6
from alarm processing
Bit 7
from messages [480.5]
Bit 8
from sequence control 1)
Bit 9
from messages [480.5]
Bit 10
from fault processing
Bit 11
from sequence control 1)
Bit 12
from setpoint processing
Bit 13
(part 2) [320.5]
from messages [480.3]
Bit 14
Bit 15
1
2
Status word 1
Meaning
1=Ready to switch on
0=Not ready to switch on
1=Ready for operation (DC link loaded, pulses disabled)
0=Not ready for operation
1=Run (voltage at output terminals)
0=Pulses disabled
1=Fault active (pulses disabled)
0=No fault
0=OFF2 active
1=No OFF2
0=OFF3 active
1=No OFF3
1=Switch-on inhibit
0=No switch-on inhibit (possible to switch on)
1=Warning active
0=No warning
1=No setpoint/actual value deviation detected
0=Setpoint/actual value deviation
1=PcD control requested (always 1; Exception: clock-
synchronized operation acc. to PROFIdrive V3)
1=Comparison value reached
0=Comparison value not reached
1=Message low voltage
0=Message no low voltage
1=Request to energize main contactor
0=Request not to energize main contactor
1=Ramp-function generator active
0=Ramp-function generator not active
1=Positive speed setpoint
0=Negative speed setpoint
Reserve
3
4
Status Word 1
r552
Status Word 1
K0032
1
B0101
B0100
Rdy for ON
1
B0103
B0102
Rdy for Oper
1
B0105
B0104
Operation
1
B0107
B0106
Fault
1
B0109
B0108
No OFF2
1
B0111
B0110
No OFF3
1
B0113
B0112
Blocked
1
B0115
B0114
Warning
1
B0117
B0116
No Deviation
1
B0121
B0120
CompV OK
1
B0123
B0122
Low Voltage
1
B0125
B0124
Energize MCon
1
B0127
B0126
RampGen active
1
B0129
B0128
Speed Setp FWD
5
6
V2.4
fp_mc_200_e.vsd
10.02.03
n959.27 = 4
Display of r552 on the PMU
15 14
13 12
11 10
Not Rdy for ON
7
6
5
4
3
Not Rdy for Oper
Not operating
1)
The sequence control system is the
internal control system (software) for
implementing the drive status (r001).
No fault
OFF2
OFF3
Not Blocked
No Warning
Deviation
CompV not OK
No Low Voltage
N.Energ.MCon
RampGen n.act.
Speed Setp REV
7
Function diagram
MASTERDRIVES MC
9
8
2
1
0